PARAMETERS | RECORDED MEASUREMENT | VALUES |
---|---|---|
Air Infiltration* | 0.3L/s/m2 | Pass |
Water Intrusion* | No leakage | Pass |
Uniform Load Structural* | ±50psf | Pass |
Shear Wall Resistance** | 475 lb x ft | Pass |
Fire Resistance (UL Certified)** | 1.5 hr | Pass |
EKOCRETE IS AN EXCLUSIVE DISTRIBUTOR OF AIRCRETE, THE LEADING MANUFACTURER OF AUTOCLAVED AERATED CONCRETE (AAC).
About AAC:
AAC (Autoclaved Aerated Concrete) is a lightweight and eco-friendly concrete, commonly known as cellular concrete.
AAC is manufactured with cutting-edge technology and natural materials including cement, lime, silica sand, and aluminum powder.
AAC products include prefabricated panels and blocks of various sizes.
AAC products are 100% natural materials, containing no foam or plastics.


A SUPERIOR ALTERNATIVE TO 3-COAT STUCCO COAT SYSTEM
Higher Quality
Easier & Quicker to Install
Lower cost per square foot
Innovation built on experience
We are the future of panels for walls and facades for residential, commercial, and office buildings.

Residential & Commercial Cladding Panel
Exterior panels for traditional wood frame system 2’x4′ and 2’x7′ panels with 2″ thickness.
Material Facts:
Exterior panels for traditional wood frame system 2’x4’ and 2’x7’ panels with 2’’ thickness
Easy and quicker to install (1/3 of the time of conventional methods)
Thin, lightweight and steel reinforced
Super smooth finish great for savings on finish coats
Does not sag, warp or deform
5.12 lbs/ft2

Our Process

Our team will meet with you to see the scope and timeline of your project.

Our expert CAD and technical team will maximize material utilization.

Your optimized quote will be sent with a delivery timeline.

Upon installation by a certified crew, we will assess the quality of the install.

One of our certified installers will be there to receive and facilitate material installation.

After approval of order, the material will ship FOB Houston and arrive in 10 days.

We will provide all material specs to help you in the approval process.
Cladding for Exterior Walls
Technical Information
TESTS
*Testing was conducted in accordance with the method designated in Testing Application Standard (TAS)
202-95 Impact & Non-impact Resistance Building Envelope Components using Uniform Static Air Pressure, and
ASTM E330/E330M-14 Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights
and Curtain Walls by Uniform Static Air Pressure Difference.
** Testing was completed as described in ASTM E564-06(2018) Standard Practice for Static Load Test for Shear
Resistance of Framed Walls for Buildings.
PRODUCT SPECIFICATIONS
PARAMETERS | UNITS | VALUES |
---|---|---|
Comprehensive Strength | psi | 580 |
Normal Density | lb/ft3 | 30.4 |
Real Density | lb/ft3 | 33.4 |
Dry Shrinkage | % | 0.02 |
Thermal Conductivity | BTU in/h ft2 °F | 0.839 |
R Value | h ft2 °F/BTU | 2.3 |
Permeability (μ) | US Perms | 6.58 |
Moisture Absorption | Wt% | 7.61 |
Water Absorption | Wt% | 22.4 |
Elastic Modulus | ksi | 326.9 |
Acoustic Insulation (2°) | STC | 28 |